SAR snap acting relay
Description
SAR snap acting relay monitor the valve supply pressure and set the valve at the safe position in case of pressure drop or pressure failure
Main features
- Rugged aluminum or 316 die-cast housing
- Stable setting pressure
- No electrical part
- High flow capacity
- Single or double acting
Options
- high temperature
Specifications
Product | SAR-S | SAR-D | ||
Acting | Single | Double | ||
Fluid | Air | |||
Signal pressure | 1.4 - 7 bar | |||
Line / Proof pressure | Max. 10 bar | |||
Operating temperature | -20 ~ +70°C | |||
Pneumatic connection | NPT 1/4 | |||
Hysteresis | 0.1 bar | |||
Flow capacity | 0.9 | |||
Body material | Aluminum / 316 SS | |||
Weight | 0.65 kg (1.2 kg) | 1.4 kg (2.5 kg) |
How to order ...
SAR | - | A | B | C | D | ||||||||
|
|||||||||||||
A - Port size | |||||||||||||
[1] - 1/4" Cv=0.9 | |||||||||||||
B - Body material | |||||||||||||
[0] - Aluminium [1] - 316 |
|||||||||||||
B - Acting | |||||||||||||
[0] - Single [1] - Double |
|||||||||||||
D - Temperature | |||||||||||||
[1] - -20 ~ +70°C (standard) [2] - -20 ~ +120°C (high temp.) [3] - -40 ~ +70°C (low temp.) |
|||||||||||||
|
|||||||||||||
SAR | - | A | B | C | D |
Code example
Code example description : SAR - 1 1 S 0 |
Product : [SAR] - Snap acting relay
Port size : [1] - 1/4" Cv=0.9
Body material : [1] - Aluminium
Acting : [S] - Single
Operating temperature : [0] - -20 ~ +70°C
|